A simplified method for the determination of void fraction during subcooled boiling in channel flow /
BOHDAL, Tadeusz. Politechnika Koszalińska - Wydział Mechaniczny, Zakład Termomechaniki i Chłodnictwa 1996 - .
A simplified method for the determination of void fraction during subcooled boiling in channel flow / Tadeusz Bohdal. - 1997.
Dane z autopsji.
The applied model of subcooled boiling in channel flow draws on relationships that describe heat transfer in frow of a two-phase mixture. It is assumed that the total heat flux supplied to the channel is partly used for the development of a new vapour phase and party for heating up the subccooled liquid to the saturation temperature. The semi-empirical model allows us to determine the void fraction during subcooled boiling in channel flow. Using the model one can study the distribution of some quantities as a function of axial co-ordinate z of the channel.
Void fraction.
Channel flow.
621.5/.6
A simplified method for the determination of void fraction during subcooled boiling in channel flow / Tadeusz Bohdal. - 1997.
Dane z autopsji.
The applied model of subcooled boiling in channel flow draws on relationships that describe heat transfer in frow of a two-phase mixture. It is assumed that the total heat flux supplied to the channel is partly used for the development of a new vapour phase and party for heating up the subccooled liquid to the saturation temperature. The semi-empirical model allows us to determine the void fraction during subcooled boiling in channel flow. Using the model one can study the distribution of some quantities as a function of axial co-ordinate z of the channel.
Void fraction.
Channel flow.