<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Infrared detection of delaminations using induction heating</title>
  </titleInfo>
  <name type="personal">
    <namePart>SUSZYŃSKI, Zbigniew.</namePart>
    <namePart type="termsOfAddress">Politechnika Koszalińska - Wydział Elektroniki, Katedra Elektroniki Ciała Stałego</namePart>
    <namePart type="date">1996 -</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>ARSOBA, Robert.</namePart>
    <namePart type="termsOfAddress">Politechnika Koszalińska - Wydział Elektroniki, Katedra Inżynierii Komputerowej</namePart>
    <namePart type="date">1996 -</namePart>
  </name>
  <name type="conference">
    <namePart>Therminic Workshop 2002 ; Madryt, Hiszpania).</namePart>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">conference publication</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">ESP</placeTerm>
    </place>
    <dateIssued encoding="marc">2002</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
  </physicalDescription>
  <abstract>The paper presents non-destructive method of investigation of multilayer structures containing conducting, material, such as thyristor structures. The proposed method is based on induction heating of examined object and infrared detection of temperature field. Infrared images of examined thyristor structures registered with the help of this method are presented. Short discussion of advantages and disadvantages of the method is also included. The main benefit from usage of the proposed method is extremely short time of registration. Therefore, this method can be applied in industry for quick quality assessment of thyristor structures. Moreover, the source of excitation does not dazzle the infrared detector. Obtained preliminary results confirm usability of the method.</abstract>
  <targetAudience authority="marctarget">specialized</targetAudience>
  <note type="statement of responsibility">Zbigniew Suszyński, Robert Arsoba.</note>
  <note>sprawozdanie jednostki (Informator o publikowanych wynikach prac naukowo-badawczych w 2002 roku Wydziału Elektroniki).</note>
  <classification authority="udc">621.382.3</classification>
  <relatedItem type="host" displayLabel="W :">
    <titleInfo>
      <title> Therminic Workshop. -</title>
    </titleInfo>
    <part>
      <text>2002, s. 50-53</text>
    </part>
  </relatedItem>
  <recordInfo>
    <recordContentSource authority="marcorg"/>
    <recordCreationDate encoding="marc">151030</recordCreationDate>
    <recordChangeDate encoding="iso8601">20180329090641.0</recordChangeDate>
    <recordIdentifier source="KOSZ 005">28</recordIdentifier>
  </recordInfo>
</mods>