000 01223nab a2200265 i 4500
001 BPP
003 BPK
005 20160407091015.0
008 140325s2009 pl f |000 0 eng
040 _cBPK
041 _aeng
044 _aPOL
080 _a621.5/.6
100 _aBOHDAL, Tadeusz.
_d1996 - .
_bPolitechnika Koszalińska - Wydział Mechaniczny,
_cKatedra Techniki Cieplnej i Chłodnictwa
245 _aCondensation of refrigerant R404A under external disturbances /
_cTadeusz Bohdal, Marcin Łomiak.
260 _c2009.
500 _aDane z autopsji.
520 _aThe paper describes results of experimental investigations of condensation of the refrigerant R404A in the flow through a coiled tube under conditions of external disturbances that occur in refrigeration units. Experiment-based correlations are obtained to describe the propagation of disturbances during development and decay of condensation of the refrigeration medium in the tubular channel.
650 0 _aCondensation.
650 0 _aInstabilities.
650 0 _aHeat transfer.
650 0 _aWave phenomena.
773 _iW :
_tArchives of Thermodynamics. -
_gVol. 30, 2009, No. 1, pp. 37-58
942 _cART
_2UKD
999 _c3650